ENISA SBOM advisory more pipeline than the CRA requires

ENISA has published its SBOM advisory. It recommends measures beyond the CRA and explains why machine builders should start differently.

Contents

  1. The advisory is industry neutral and does not mention mechanical engineering
  2. ENISA goes beyond the CRA and the BSI guideline
  3. For supplied firmware and small manufacturers the advisory remains vague
  4. In mechanical engineering the SBOM often already lacks the firmware version
  5. First inventory and risk assessment, signature last

The advisory is industry neutral and does not mention mechanical engineering

ENISA developed the text from a late 2025 draft and coordinated it with the CRA Expert Group. Further revisions are announced. Substantively, the advisory follows the principles of the Secure by Design and Default playbook (ENISA playbook).

According to ENISA, the document is industry neutral and does not mention mechanical engineering. In addition to architecture and a threat model it lists open source tools for each lifecycle phase. Where such tools reach their limits, see the overview SBOM tools and their limits.

ENISA goes beyond the CRA and the BSI guideline

ENISA states that the advisory contains recommendations that can go beyond the CRA requirements. How far it goes becomes clear when compared with the text of Regulation (EU) 2024/2847 and the BSI TR-03183-2, which the advisory itself cites as the basis for data fields:

CRA BSI TR-03183-2 (Version 2.1.0) ENISA advisory
Depth at least top-level dependencies (Ann. I Part II No. 1) product-of-supply SBOM as MUST no specific minimum depth
SBOM type not specified build SBOM, or equivalent information if no build entry point at the build
Format common and machine-readable (Ann. I Part II No. 1) CycloneDX from 1.6 or SPDX from 3.0.1, JSON or XML common and machine-readable
Signature not required recommendation (“should”) in the explanatory annex fixed step after validation
Disclosure stored in technical documentation, to market surveillance on justified request (Ann. VII No. 8), to users voluntarily (Ann. II No. 9) provider responsible for availability of referenced SBOMs controlled disclosure with access control
Binding effect regulation technical guideline, not a legal norm explicitly non-binding

The depth listed in the CRA column is our reading. We equate the top-level dependencies with the TR’s top-level SBOM, i.e., the primary component together with everything it directly depends on. None of the three sources states this explicitly. From this follows a clear tiering: the TR requires more depth than the CRA, and ENISA requires more infrastructure than both.

In practice we repeatedly encounter the same conflict regarding disclosure. Customers want to see the machine’s SBOM, manufacturers refuse to provide it. Under the CRA customers have no claim to it. The advisory supports this reluctance: as a countermeasure against leaking version and supplier relationship details it itself names controlled disclosure. How the CRA distributes duties around SBOMs and vulnerabilities is explained in Who is responsible for vulnerabilities and SBOMs.

For supplied firmware and small manufacturers the advisory remains vague

For binary supplied components the advisory refers to an analysed SBOM. If such components cannot be fully analysed, manufacturers should document the “known unknowns.” The TR classifies firmware images as archives that cannot be broken down into their origin components. Neither source specifies how a manufacturer should delimit top-level dependencies for such an image. For a purchased controller with a runtime and a fieldbus stack, what ends up in the SBOM can therefore vary.

The second unresolved point concerns the target audience. The advisory addresses SMEs that are starting with SBOMs. For integration it then presupposes “mature continuous integration infrastructure and standardised build processes” and uses the phrase “must be established,” even though it declares itself non-binding. According to ENISA’s SBOM Adoption State of Play 2026, on which the advisory relies, 41 percent of respondents want to fully automate generation per release or build. Twenty-six percent expect fully automated maintenance over the support period. ENISA itself calls automation after the build “work in progress.”

In mechanical engineering the SBOM often already lacks the firmware version

A packaging machine that integrates a purchased PLC, HMI panel and remote access router has no in-house build pipeline to which ENISA’s pipeline could attach. The software is inside supplier components and arrives as binary images. Device manufacturers that build their own firmware have it easier: Yocto, Zephyr and Linux already produce SPDX; the build only needs to enable that function. Those who build their own firmware and run CI should use it. For these manufacturers ENISA’s approach fits.

At machine builders the problem is one step earlier. We often see components kept in inventory and reordered as needed. Between two purchases the firmware version can change, and production records nobody notes it down. Two ostensibly identical packaging machines can therefore leave the factory with different firmware states.

For the SBOM the relevant state is the one shipped. That is almost always the firmware installed during assembly, at the factory acceptance test, or at commissioning on PLCs, panels and routers. Production must record that version per machine. Many manufacturers will need to change their production processes before an SBOM for the machine is possible.

Diagram: SBOM in mechanical engineering using a packaging machine as an example. On the left the machine builder assembles purchased components from three suppliers (PLC with runtime and fieldbus stack, HMI panel with visualization and operator software, remote access router) and programs the PLC; the firmware arrives as a binary image. Firmware versions must be entered manually per machine; for purchased software on the panel an automated build may be possible. On the right a component vendor with its own firmware runs a build pipeline: its own build with Yocto, Zephyr or Linux creates a build SBOM in SPDX format during the build, then—per ENISA recommendation—validate, sign and control disclosure.

Which SBOM does the CRA require from you?

Our template gives you a structure for your product SBOM that you can incorporate into the technical documentation.

Download template

First inventory and risk assessment, signature last

We recommend that machine builders produce the SBOM at the depth required by the CRA—and no deeper for now. The larger gaps are usually in the cybersecurity risk assessment, and the effort belongs there first. You will spot this gap in projects when questions like “Do we need secure boot?” arise but no one knows which installed component is actually risky. Another sign is the objection that the firmware version of the safety PLC does not matter because it is not connected to the internet. As long as it is unclear where the product’s risks lie, SBOM questions are premature. How the risk assessment is divided between manufacturer and operator is shown in Risk assessment under CRA, MVO and NIS-2.

We consider signature and artifact binding to be the last step. As long as the firmware version of automation components cannot be determined, signing secures a list whose content may be incorrect.

For the initial step we agree with ENISA. It recommends starting at the build and first determining integration points. This entry point does not yet require a signature. Which duties besides the SBOM belong in the technical documentation is summarised in CRA duties for manufacturers.

For software and device manufacturers with their own CI the advisory is a useful working basis. It misses the actual needs of machine builders.

Determine SBOM depth for your machine

We will clarify with you which SBOM your machine needs under the CRA and which steps in production and risk assessment must come first.